Compensated Neutron Tool
Download .PDF Brochure
|
Parameters Logged:
|
| |
Natural Gamma (1)
|
2.2 x 10.1 cm (0.875 x 4.0 in.)
NaI Scintillation
Offset: 30.5 cm (12 in.)
|
0-10,000 API units
|
|
Deep Guard Resistivity (2)
|
Upper guard, measure and lower guard electrodes, 3 m (10 ft.)
Offset for measure electrode:152.4 cm (60 in.)
|
0 to 20,000 CPS
|
|
Neutron Detector, Far Spacing (3)
|
He3 3.8 x 24.4 cm (1.5 x 9.6 in.)
64.3 cm (25.3 in.) spacing
Offset: 209.8 cm (82.6 in.)
|
0 to 5,000 CPS
|
| |
Neutron Detector, Near Spacing (4)
|
He3 3.8 x 10.1 cm (1.5 x 4.0 in.)
25.4 cm (10.0 in.) spacing
Offset: 246.4 cm (97 in.)
|
-10 to 100% porosity
|
|
Radioactive Source (5)
|
5 Ci AmBe 241 neutron source, bullplug
Offset: 289.5 cm (114 in.)
|
0 to 40,000 ohm meters
|
|
The Compensated Neutron tool contains a two detector, neutron system which uses a 5.0 Curie, Am241Be source to record neutron porosity of the formation. Additionally, the tool also records short and long neutron counts, natural gamma and a deep guard resistivity.
|
Specifications:
|
|
Diameter
|
5.08 cm (2.0 in.)
|
|
Length
|
283.5 cm (111.6 in.)
|
|
Max. Pressure
|
232 kg/cc (3300 PSI)
|
|
Weight
|
25 kg (55 lb.)
|
|
Max. Temperature
|
85 C (185 F)
|
|
Logging Speed
|
9 m/min. (30 ft./min.)
|
|
Tool Voltage
|
70 VDC
|
Example Log Image:

|
 |
|
|